‘ROLYCAB’ make 3 Core Flat Submersible Cables are manufactured from pure electrolytic grade copper, which is drawn, annealed on-line and bunched on automatic machines to ensure flexibility and unifrom resistance. The conductors are insulated with special grade of PVC. Outer sheath consists of highly abrasion resistant PVC compound impervious to grease, oil, water, etc.
Submersible Cables
Certified by :
Construction
- Conductor:
- Annealed Electrolytic Plain/ Tinned Multi stranded copper conductor.
- Insulation:
- Polyvinyl Chloride (PVC) HR-Grade
- Colour code:
- 2 Core: Red/Black
- 3 Core: Red/Black/Green
- 4 Core: Red/Yellow/Blue/Black
- 5 Core and above: White insulation with numbers for identification
- Collective screen (application for control cables with shielding):
- Aluminium Mylar tape along with 0.50sq mm drain wire
- Inner sheath:
- PVC (Polyvinyl Chloride) black
- Armored:
- G.I. wire of 0.90mm/1.40mm/4mm X 0.80mm
- Outer sheath:
- PVC (Polyvinyl Chloride), Type: ST2, FR or FRLS
- Voltage Grade:
- 300V/600V/ 1100V as per requirement of customer.
‘ROLYCAB’ MAKE-3 Core Submersible Flat Cable(with IS 694:1990-ISI Marked) upto and including 1100V. AC,Hz50,3Ph
| Conductor | Insulation | Sheath | Conductor resistance @20° C(max) Ohms/km | Current Carrying Capacity @40° Amps Ohms/km | ||||
| Area (Nom.)Sq mm | No/Dia. Of strands mm | Thickness (Nom.)mm |
| |||||
| 1.5 | 22/0.3 | 0.8 | 1.1 | 11.6×5.5 | 12.10 | 16 | ||
| 2.5 | 36/0.3 | 0.9 | 1.2 | 13.9×6.4 | 7.41 | 22 | ||
| 16.00 | 56/0.3 | 1.0 | 1.3 | 16.1×7.1 | 4.95 | 29 | ||
Note:
1) Insulation thickness, Sheath thickness and Overall Dimensions given in this table are nominal value within limit of standard.
2) The strand diameter are nominal. Construction of the conductor is designed to satisfy the requirement of conductor resistance as per IS 8130:1984
‘ROLYCAB’ MAKE-3 Core Submersible Flat Cable(as per IS 694) upto and including 1100V AC,Hz50,3Ph
| Conductor | Insulation | Sheath | Conductor resistance @20° C(max) Ohms/km | Current Carrying Capacity @40° Amps Ohms/km | ||||
| Area (Nom.)Sq mm | No/Dia. Of strands mm | Thickness (Nom.)mm |
| |||||
| 6.00 | 84/0.3 | 1.1 | 1.4 | 18.6×8.0 | 3.30 | 37 | ||
| 10.00 | 80/0.4 or 140/0.03 | 1.3 | 1.6 | 23.4×10.00 | 1.91 | 51 | ||
| 16.00 | 126/0.4 or 226/0.3 | 1.4 | 1.8 | 27.0×11.4 | 1.21 | 68 | ||
Cable Construction & Colour Code:
| For Asian, African Markets | Core Colors | For European Markets |
| Red, Yellow, Blue | 3 Core | Black, Blue, Brown |
| Black | Sheath | Black |
Note : Outer sheath color other than black are available on request with MOQ.
Correction table
| Ambient Temperature (Deg. C) | 25 | 30 | 35 | 40 | 45 | 50 |
| Factor | 1.18 | 1.12 | 1.06 | 1.00 | 1.94 | 0.88 |