    SPECIFICATIONS:

    • Conductors
      16 Awg(1.29mm) standard for 1-pair and 20Awg (0.81mm) for multipair cables. Conductors such as 1.381 (1.5 mm2) or 18Awg (1.02) or stranded 7 * 0.3 (0.5mm2) also available on request.
      Matched homogenous wire materials are used to obtain best results.
    • Insulation
      Primarily insulation of extruded PVC, 85oC grade or 105oC grade is standard. Insulation such as LDPE, Fiber glass or asbestos braid is available as optional.
    • Pair
      Insulated pair is twisted with a lay of 65 to 75mm.
    • Shield
      Twisted pair or pair bundle is taped with Al-Mylar tape with 25% overlap, 100% shield, with 7 * 0.3mm dia, tinned copper wire in continuous contact, with AI side of tape. Cables with each pair shielded and overall pair bundle shielded also available.
    • Intermediate Sheath
      Shielded pair or pair bundle is provided with soft extruded PVC, 85oC (105oC) grade.
    • Armor
      Served, Annealed GI wire armor.
    • Jacked
      Extruded PVC, 85oC or 105oC grade
    • Telephone Pair
      Cables with six or more pairs are provided with, 2 Nos. * 20Awg solid conductors PVC insulated
    • Cable Characteristics
      Cable with low L/R ratio, critical Capacitance and inductance values are designed to suit customer needs; to meet stringent requirement of secondary instrumentation.

    Table 1: Maximum Inductance

    Cable Type Conductor Material Max Inductance Micro H/Mtrs
    +ve -ve
    KX Ni Cr Ni Al Extension Cable 4.00
    WX Fe Cu Ni Compensating Cable 8.00
    VX(KXA) Cu Constantan Compensating Cable 1.20
    JX Fe Constantan Extension Cable 8.00
    TX Cu Constantan Extension Cable 1.20
    SX Cu Cu Ni Compensating Cable 1.20
    EX Ni Cr Constantan Extension Cable 4.00
    NX Ni Cr Cu Ni Extension Cable 4.00
    1.00

    Table 2: Loop Resistance Thermocouple Extension/Compensating Cables

    Conductor Detail Loop Resistance(ohms/mtr)+10%@20°C
    Cable Type
    AWG Dia(mm) Cross Sec.Area sqmm KX VX KX (A) JX TX SX/RX EX XK
    16 1.29 1.31 0.76 0.39 0.46 0.39 0.104 0.97 0.97
    18 1.02 0.823 1.21 0.62 0.76 0.62 0.169 1.52 1.52
    20 0.81 0.50 1.98 0.97 1.20 0.97 0.266 2.50 2.50

    Table 3: International Color Codes For Thermocouple Cable Insulation

    Conductor Combination ANSI MC 96.1 AMERICAN IS:8784 INDIAN BS:1843 BRITISH DIN 43710-4 GERMAN NFE 18001 FRENCH
    EXTENSION
    + Chromal
    – Alumel
    row1-1 row1-2 row1-3 row1-4 row1-5
    + Iron
    – Constantan
    row2-1 row2-2 row2-3
    + Copper
    – Constantan
    row3-1 row3-2 row3-3 row3-4 row3-5
    + Chromel
    – Constantan
    row4-1 row4-3 row4-4
    + Nicrosil
    – Nisil
    row5-1 row5-3
    COMPENSATION
    + Copper
    – Constantan
    row6-1 row6-2 row6-3 row6-4 row6-5
    + Copper
    – Cupronic
    row7-1 row7-2 row7-3 row7-4 row7-5